Sign In | Join Free | My infospaceinc.com
China Nanjing Kelisaike Safety Equipment Co., Ltd. logo
Nanjing Kelisaike Safety Equipment Co., Ltd.
Nanjing Kelisaike Safety Equipment Co., Ltd.
Verified Supplier

3 Years

Home > Fixed Gas Detector >

K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output

Nanjing Kelisaike Safety Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output

Stock : 1PC

MOQ : 1

Voltage : DC 24 V

Detection of gas : Combustible and toxic gases

Signal output : 4 to 20 mA

Detection range : 0-2000 ppm

Electric control device : Solid relay output

Port : Shanghai

Explosion-proof grade : Exd IIC T6

Certification : CE

Certificate : CE

High alarm : 100 ppm

Place of Origin : Nanjing,China

Brand Name : KELISAIKE

Model Number : Per the description

Packaging Details : Standard neutral carton box

Supply Ability : 1000 Piece/Pieces per Month

Price : $220.00 - $310.00/pieces

Use : Safety alarm

Low alarm : 50 ppm

Operating Temperature : -20 degree ~ +50 degree

Contact Now

Explosion Proof Fixed Gas Detector for Hazardous Areas
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output

K800 is an industrial fixed gas monitoring detector developed for applications where combustible or toxic gas leakage needs to be continuously monitored.

With an Ex d IIC T6 explosion-proof enclosure and IP66 protection, the detector is designed for demanding industrial environments. Depending on the gas being monitored, K800 can be equipped with catalytic, electrochemical or infrared sensor technology.

The system supports 4-20mA, RS485 MODBUS and relay outputs, allowing the detector to communicate with gas detection controllers, PLC or DCS systems.


Gas Detection Options

The K800 platform supports a wide range of gases, including:

  • O2
  • CH4 / LEL
  • CO
  • H2S
  • SO2
  • NH3
  • Cl2
  • NO2
  • NO
  • O3
  • PH3
  • H2
  • HF
  • HCl
  • HCN
  • VOC
  • CO2
  • C3H8

For example, the standard datasheet lists CH4 at 0-100%LEL, CO at 0-1000/2000 ppm, H2S at 0-200 ppm and O2 at 0-25/30%vol, with the exact range depending on the selected sensor configuration.


Key Features
1) Digital and analog outputs

2) LED status indicator light for alarm conditions

3) The relay can trigger alarms or process control system

4) Three models available for measuring toxic gases, VOCs, or combustible gases

5) Explosion-proof case

6) CERTIFICATIONS: CE, CMC, Ex, MA (SAFETY CERTIFICATE OF APPROVAL FOR COAL MINING PRODUCTS IN CHINA).


Industrial Integration

K800 can provide gas concentration signals to a central control system. Its relay outputs can also be used for alarm linkage and external equipment such as ventilation fans.

This makes it suitable for continuous gas monitoring projects where local detection and centralized control are both required.

Product Description Version 3 — PLC / DCS Integration

Fixed Gas Detector with 4-20mA and RS485 MODBUS

K800 is designed for integration into industrial gas detection and automation systems.

The detector provides 4-20mA analog output, RS485 MODBUS communication and 3 relay outputs, allowing gas concentration data and alarm signals to be transferred to PLC, DCS, gas controllers or other control equipment.


Main Specifications

  • Model: K800 Fixed Gas Detector
  • Sampling method: Natural diffusion
  • Power supply: 24V DC
  • Analog output: 4-20mA
  • Digital communication: RS485 MODBUS
  • Relay: 3 relay outputs
  • Optional communication: HART
  • Display: 4-digit LED / LCD / OLED
  • Protection: IP66
  • Explosion-proof: Ex d IIC T6
  • Response time: Up to T90 ≤30 seconds for many standard configurations
  • Operating temperature: approximately -20°C to +50°C, with heater configuration available for lower temperatures
  • Housing: YL113 aluminum + 304L stainless steel
  • Cable connection: M20×1.5


Typical System Connection

K800 can transmit 4-20mA or RS485 signals to a K1000 controller, PLC system or other central control unit.

For projects requiring automatic alarm linkage, the relay outputs can be configured to trigger external devices after the gas concentration reaches the preset alarm threshold.

















K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
Product Details Show
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
Detection gas list
Detection gas
Range
Accuracy
90% response time
Min readout
Low/High alarm
PH3
0-5-2000ppm
±5%(F.S)
≤25s
0.01ppm
0.3ppm/5ppm
O2
0-30%vol
±5%(F.S)
≤15s
0.1%vol
18%vol/23%vol
LPG(Ex)
0-100%LEL
±5%(F.S)
≤5s
1%LEL
25%lel/50%lel
CO
0-2000 ppm
±5%(F.S)
≤25s
1 ppm
50ppm/100ppm
H2S
0-100 ppm
±5%(F.S)
≤30s
1 ppm
10ppm/20ppm
CH4
0-100%LEL
±5%(F.S)
≤5s
1%LEL
25%lel/50%lel
NH3
0-100ppm
±5%(F.S)
≤50s
1 ppm
25 ppm /50 ppm
O3
0-20ppm
±5%(F.S)
≤60s
0.01ppm
0.2ppm/0.4ppm
CI2
0-20 ppm
±5%(F.S)
≤30s
0.1 ppm
1 ppm /10 ppm
H2
0-1000 ppm
±5%(F.S)
≤60s
1 ppm
50ppm /100ppm
SO2
0-100 ppm
±5%(F.S)
≤30s
0.1 ppm
2 ppm /10 ppm
NO
0-250 ppm
±5%(F.S)
≤60s
1 ppm
25ppm/50 ppm
NO2
0-20 ppm
±5%(F.S)
≤25s
0.1 ppm
3ppm/10ppm
Infrared CO2
0-5%vol
±5%(F.S)
≤60s
0.1%vol
1%vol/2%vol
Infrared CH4
0-5%vol
±5%(F.S)
≤60s
0.1%vol
0.1%/0.15%vol
Infrared C3H8
0-5%vol
±5%(F.S)
≤60s
0.1%vol
0.1%/0.15%vol
Product Processing
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
Product Packing
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
Certificates
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output
Why Choose Us

Why choose KELISAIKE?

1. Mutual benefits: We are a manufacturer, so we can offer products of the same quality at the best prices.

2. Professional engineers: We have seasoned engineers with over 10 years' experience in gas detection field. With various hi-tech equipment, we make products with higher accuracy and stability.

3. Customization: Thanks to our strong R&D team, we can customize our products at your request.

4. Free OEM service: a) Silk-print your Logo (≥ 100 PCS). b) Design your colour box packing (≥ 200 PCS).

5. Mixed order: We accept mixed orders, with different models and small quantity orders.

6. After service: (a) 1 Year warranty. (b) If you found any of our products of inferior-quality, we will send you new ones to replace them for free in the next order after verification.

>>>FAQs:

Q: Can I order one piece as a sample to test the quality?
A: Yes, we recommend ordering sample for quality check before large quantity order.

Q: May I have your catalogue and price list for trial order in MOQ quantity?
A: All our products are shown on Aalibaba.com; please have a detailed look and choose the interested models in the website. Or you can send email to us directly for more product information.

Q: If I order a large quantity, what's the best price?
A: Please send the detailed enquiry to us, including item model number, quantity for each item, quality requirement, Logo and payment terms, shipping method, discharge place, etc. We will make an accurate quotation to you at the earliest time.


Product Tags:

DC 24V Fixed Hydrogen Gas Detector

      

Electric Control Fixed Hydrogen Gas Detector

      

Solid Relay Output Industrial Gas Detector

      
Quality K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output for sale

K800 Ex d IIC T6 Fixed Gas Detector for Hazardous Areas with 4-20mA and RS485 Output Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Nanjing Kelisaike Safety Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)