type : KF200

Model Number : WT602

Brand Name : KELISAIKE

Place of Origin : Jiangsu, China

customized support : OEM, ODM, OBM

Product name : k800 Fixed gas detector

Detection of gas : Combustible and toxic gases

Output signals : 4-20mA/RS485

Nominal voltage : DC 24V gas leak detector

Alarm system : Vibration alarm with light,sound

Explosion-proof grade : Exibd II CT6

Size : 183*143*107mm

Service Life : 2-5 years Fixed gas detector

Weight : 2000g Fixed gas detector

MOQ : 1

Price : $1,670

Contact Now

High Accuracy Heat Tracing CEMS UV Hot-Wet SO2, NOx, O2, CO, CO2 Gas Analyzer


The analyzer based on UV absorption spectroscopy and chemometric algorithms to measure SO2, NOx, O2, NH3, Cl2, O3, H2S and other gases concentration, with high accuracy, high reliability, fast response time, wide application and other characteristics, the indicators have reached or exceeded similar products, it can be widely used in environmental online monitoring, industrial control, security monitoring and other occasions.

>>>Key Features

Full spectrum measurement and DOAS (Differential Optical Absorption Spectroscopy) algorithm, excelling in accuracy, repeatability and anti-interference with moisture, dust.

Modular design and no moving parts, higher reliability and easier maintenance.

Pulse Xenon Lamp used as light source with over 10-year lifetime.

The adoption of diode array sensor enables instant spectrum acquisition and rapid response.



>>> Features and Benefits
1. Analyzer uses the following optical technology platform to get the UV absorption spectrum, the technology platform consists of light source, gas chamber, fiber optics and spectroscopy (including the diaphragm, holographic gratings, linear array detector) and other optical components.

2. UV-visible light emitted by the optical window into the gas chamber, is absorbed by the sample gas flowing through the measured gas chamber, carrying the tested sample gas absorbs light through the lens after gathering information coupled into optical fiber through the optical fiber transmission into the spectrometer splitting, sampling, to obtain the absorption spectrum of the gas.

3. Use DOAS technology spectrum analysis, can analyze the concentration of the gas in the relevant component.

>>> Measuring principle

1) The light source emits ultraviolet beam which transfers to gas cell through optical fiber.

2) After absorption by measuring gas, the light beam transfers through optical fiber to spectrometer.

3) Being dispersed through the grating, and converted into electric signal by the array sensor, a continuous absorption spectrum of measuring gas is thereafter obtained.


>>>Technology Comparison

Item UV Hot-Wet Method NDIR
Spectral Range Complete and continuous absorption spectra obtained through holographic grating and diode array detection Non Dispersive, characteristic absorption spectra obtained through band-pass filter
Linear Response High wavelength resolution secures linear response band-pass filtration compromises linear response
SO2 Loss Hot-wet prohibits SO2 dissolution Condensation inevitably causes SO2 loss
Sampling System Heat tracing. Requests only dust filtration, simple and no corrosive Cold-dry. Requests dust filtration, condensation, water removal and corrosion proof
Zero Calibration Period Long (DOAS algorithm) Short
Anti-Interference The combination of complete & continuous absorption spectra, high wavelength resolution, DAOS algorithm erases interference from dust, moisture and background gases Vulnerable to moisture interference
Gas Cell Connected by optical fiber, easy to replace and low maintenance cost Complex to replace and maintenance
Maintenance
Reliability No moving parts Moving parts existed

>>>Technical Specifications

SO2, NOx Analyzer
Technical Principle UV-DOAS
Installation type Hot-wet Extractive
Measurement Range 0~200ppm, 0~1000ppm, 0~3000ppm
Zero Drift ≤ ±2%F.S.
Span Drift ≤ ±2%F.S.
Accuracy ≤ ±1%
Response Time(T90) ≤ 60s
Linearity ≤ ±1%F.S.
O2 Analyzer
Technical Principle Zirconia/Electrochemical
Measurement Range 0~25%
Response Time(T90) ≤ 60s
Linearity ≤ ±2%F.S.
CO, CO2 Analyzer
Technical Principle NDIR
Installation type Extractive
CO Measurement Range 0~1000 ppm
CO2 Measurement Range 0~20%
Zero Drift ≤ ±2%F.S.
Span Drift ≤ ±2%F.S.
Accuracy ≤ ±1%
Response Time(T90) ≤ 60s
Linearity ≤ ±2%F.S.


Technical Data for UV gas analyzer

Project Indicators
SO2 Detection range Min:0-50ppm,Max:0-100%,
NO Detection range Min:0-50ppm,Max:0-100%,
O2 Detection range 0-25%, Electrochemical or zirconia
Linearity error ≤±1%F.S.
Repeatability ≤1%
Zero drift ≤±1%F.S./ week
Span drift ≤±1%F.S./week
Ambient temperature 5ºC~45ºC
Response time(T90) <10s
Size 19" *3U*320mm
Analog interface 3-way 4-20mA output,2-way 4-20mA input
Data interface 4-way switch input; 8-way relay output
Communication Interface 1-way RS-232,1-way RS-485(Supports Mod-bus protocol)
Power 220VAC/50Hz 100W
Protection grade IP42
Sample gas input and output interface Ø6 Tube Fittings


>>> FAQ
1.How about the Delivery time?
Samples will be prepared within 15 Days after 100% T/T in advance payment. QTY order will be delivered in 30 days.
2.What kind of payments does KELISAIKE support?
T/T, L/C, Western Union, Cash all are accepted.
3.What's the MOQ?
Generally speaking, the MOQ is 5PCS, but we can also provide you samples for quality inspection.
4.Do you charge for the samples?
According to our company policy,we just charge the samples based on EXW price.
5.Can you produce according to customers' design?
Sure.We are professional maunfacturer and OEM is welcome

Company Information

Online Dust Monitor for Continuous Dust Analyzer

Online Dust Monitor for Continuous Dust Analyzer

Online Dust Monitor for Continuous Dust Analyzer

Online Dust Monitor for Continuous Dust Analyzer

FAQ

Q1: Are you a trading company or manufacturer ?

A1: We aremanufacturer.

Q2: What about the payment method?

A2: T/T, Paypal, Western Union, L/C is available

Q3: Does your company accept customization?

A3: We do customizing service for customers.

Q4: What about the Shipment?

A4: We’ll choose proper transportation mode based on the weight of goods, usually arrange shipment by air express such as DHL,FEDEX,TNT or UPS.

Q5: What about after-sale service?

A5:12 months warranty for all kinds of products.

Add: No.9 Gaohu Road, Nanjing, 211100, China

Tel: +86 15050595939

Fax: +86 025 86644689

Skype: Saran Tong

Website: www.njklsk.com


Product Tags:

continuous dust analyzer monitor

      

online dust measurement device

      

fixed gas detector with warranty

      
Quality Online Dust Monitor for Continuous Dust Analyzer for sale

Online Dust Monitor for Continuous Dust Analyzer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Nanjing Kelisaike Safety Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)